Instructions for Use

Quick recording guide

NOTE: Before using the device for the first time, read the instructions for use carefully and follow the recommendations and suggestions. This chapter only includes short instructions for the use of the MESI mTABLET ECG. For detailed descriptions of individual functions of the device, see chapter PERFORMING ECG RECORD. Please keep for future reference.

NOTE: Before starting the measurement make sure that there is no source of intense electromagnetic interference in the vicinity of the equipment (radio transmitters, mobile phones) which could have an adverse effect on the performance of the MESI mTABLET ECG.

NOTE: The MESI mTABLET ECG is intended for use in medical institutions, where recordings must be carried out by adequately trained medical personnel. The MESI mTABLET ECG is not intended for home use.

4.1 PREPARATION FOR RECORDING

⚠️MESI ECG MODULE is part of the MESI mTABLET ECG system. Before starting a measurement be sure that you are familiar with all devices and their instructions which are part of the system. MESI mTABLET ECG contains MESI mTABLET (MTABSYSW), MESI ECG MODULE (ECGSYS) and MESI LARGE CHARGING PLATE (CS4SYS).

Careful preparation of the patient and correct positioning of the electrodes are fundamental in obtaining an ECG recording of high quality.

4.1.1 PAIRING WITH MESI mTABLET UNIT

Before any recordings can be performed the MESI ECG UNIT module needs to be paired to your MESI mTABLET UNIT. For detailed instructions please follow instructions in chapter 5.1.4 Pairing.

4.1.2 CONNECTING PATIENT CABLE

Patient cable is disconnected during storage and transportation. Before first use please connect main connector to patient cable port on the device.

MESI mTABLET ECG - Connecting patient cable

4.1.3 PATIENT PREPARATION

Step 1

The patient needs to expose the skin and lie down on examination bed in a supine position. Make sure the patient is comfortable and relaxed and does not feel cold. The individual should lie back on a suitably large examination bed with arms and hands extended along the sides of the body: this will minimize the likelihood of the ECG trace being affected by muscle tremor.

Step 2

Clean the skin thoroughly with alcohol or ether at the areas where the electrodes will be placed. In some cases, it may be necessary to shave the hair in these areas to provide a better skin surface for good electrical contact.

Step 3

Place electrodes on patient cable. The following figure shows the standard positioning of the disposable electrodes.

4.1.4 PERFORMING ECG RECORDING

Step 1

On your MESI mTABLET UNIT, select existing patient (1) or add a new one (2).

Patient preparation - MESI mTABLET ABI

Step 2

After selecting the patient, please select the ECG measurement in the application menu

MESI mTABLET ECG - PERFORMING ECG RECORDING - Step 2

NOTE: For additional information please see MESI mTABLET instruction manual – chapter PATIENT MANAGEMENT

Step 3

Press start to begin the recording process.

MESI mTABLET ECG - PERFORMING ECG RECORDING - Step 3

Step 4

Select recording parameters such as speed, sensitivity and filters by pressing the settings button (1).

MESI mTABLET ECG - PERFORMING ECG RECORDING - Step 4,5

Step 5

When the ECG signal is stable you can begin the recording process by pressing AUTO for automatic 10s signal acquisition (2) or MANUAL for up to 5 minutes ECG signal capture (3).

MESI mTABLET ECG - PERFORMING ECG RECORDING - Step 4,5

NOTE: For more information about advanced functions please see chapter Performing ECG recording / Recording settings and filters.

4.2 RESULTS

After the recording is complete, you will be directed automatically to the result page where additional parameters of signal can be viewed by scrolling up and down. Top menu navigation provides you with basic actions such as:

MESI mTABLET ECG - Results

Unless deleting or retaking the ECG recording, results will be saved to mRECORDS where medical specialist responsible for ECG examination can interpret the patient ECG signal.

NOTE: For more information about the result screen, please see chapter Reviewing ECG (p. 33).

NOTE: For bigger display and additional functions rotate the tablet 90 degrees into landscape mode. This will bring the result screen into full screen mode where you have a better overview with advanced display functions by pressing the setting button.